Temperature switches are employed in machine building and other industrial applications for limiting temperature. They monitor the temperature and react at a predefined point. To safeguard from overheating they either switch the gear or machine off or switch on a fan for cooling. Based on the task accessible, temperature switches operate as either normally-closed or normally-open switches. Three switch types are believed for industrial applications:
Electronic switches
Example: Electrical WIKA temperature switch TSD-30
Where a higher accuracy is requested, the operator should resort to an electronic switch. With this particular instrument, you can change the limit values yourself and set several switch points. Electronic temperature switches may be used beyond their actual function ? yet another analogue output (e.g. 4 ? 20 mA) enables further processing of the signal and therefore continuous temperature monitoring as well.
Furthermore, switches of the type could be fitted with digital communication (IO-Link). The benefits of these are an even faster parametrisation alongside extended diagnostics functions and integration into automated processes. Via an LED display, an on-site indication can be provided.
The wide usability of the electronics is reflected in the purchase costs. In addition, it sets limits on the operating temperature. Its maximum value is, typically,150 �C, that is sufficient in most of applications, however. To be able to fulfil their tasks, electronic temperature switches need, and a power source, yet another contactor since their transistor only switches suprisingly low power.
Dial thermometers with switch contact
Example: WIKA expansion thermometer with switch contact SB15
The outstanding feature of dial thermometers with switch contacts is the wide temperature range. In general, expansion thermometers are used for industrial applications. They cover ? based on the version ? temperatures around 400�C.
This instrument type also offers the operator the chance of selecting multiple switch points and setting them independently. Additionally it is suitable for switching in the low-voltage range (250 VAC). An additional contactor isn’t needed. Dial thermometers with switch contacts function without additional power supply and, furthermore, offer an on-site display. A further processing of the signal is not possible, however.
With regard to price and performance, the switch solution described here is positioned in the mid range.
Bimetal temperature switch
Example: WIKA bimetal temperature switch model TFS35
Bimetal temperature switches have become compact, cost-effective and also have been designed for a variety of applications. Twitching can also switch with low voltages up to 250 VAC, sufficient reason for this they can manage with no additional contactor.
Bimetal temperature switches operate with lower accuracy. Working exclusively as switches, they neither provide a local display, nor do they enable any processing of the signal. Their compact design also only permits a restricted temperature range (max. 200 �C), since the plug connection is quite close to the hot area.