Cleaning of submersible pressure transmitters or level probes

If the precise pressure sensor design of the submersible pressure transmitter or level probe is selected to gauge the filling levels, this often means that the probe can be used under environmental requirements which would cause failure of common level sensors.
The most adverse conditions such as soiled media, abrasive ingredients and sludge when found in wastewater treatment plants, brackish and wastewater tanks and even digester towers, impose special requirements on the design of a submersible pressure transmitter. One of many requirements on a submersible pressure transmitter is to obtain the lowest possible susceptibility to contamination or build-up of the pressure sensor by optimizing its design. This is why the typical design of a pressure transmitter with narrow pressure ports is not used within level probes because it would have a tendency to clog such applications.
The design of the submersible pressure transmitter and its own pressurised sensor diaphragm is optimised in order to achieve very low susceptibility to contamination. However, continuous operation in soiled media may lead to sticking of dirt particles on the stainless diaphragm. To obtain the highest accuracy and fastest response times in case of level change, the thickness of the stainless steel diaphragm has already been minimised ex factory to just a couple microns. Therefore, cleaning of Rich must be carried out with caution. Always stay away from sharp or edged tools. It is also strongly advised not to use the commonly used screwdrivers or pens.
If cleaning of the sensor diaphragm is necessary, then rinse it utilizing a weak water jet or clean it carefully using compressed air. Damage of the diaphragm due to denting or notching, even though it seems to be purely superficial, results in significant losses in the accuracy of level measurement. Deformation of the diaphragm often shifts the zero point of the pressure measurement in the internal electronic measurement system and also distorts the output signal linearisation which has been adjusted ex works to the undamaged diaphragm. Thus, the submersible pressure transmitter with damaged diaphragm generates falsified measurement of the existing filling level and, therefore, can’t be considered a reliable measuring instrument any more. Thus, complete replacement of the damaged instrument is completely necessary.
Please find further information with this topic on our information platform ?Hydrostatic level measurement?