Pressure sensor with I�C communication ? possibilities and boundary conditions

I�C was designed to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. For Payback being, it isn’t only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but also pressure sensors remote from customer electronics.
Remote sensors usually have the benefit of being less sensitive to contaminated or aggressive media and being able to measure directly at the procedure. In the case of sensors mounted on the circuit board, the sensor element is, in many cases, exposed right to the medium. With remote sensors, steel or ceramic generally serve as the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than having an analogue signal:
In the info protocol, in addition to the pressure value, a temperature value and diagnostic information (for example an integrity test of the data transfer) could be transmitted via a status byte.
Several pressure sensors can be connected to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On the customer side, in contrast to the use of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary because the pressure value is already within digital form. This plays a part in faster and easier signal processing.
The electronics for communication could be constructed with standard components easily available on the market.
Often, I�C signal pressure sensors may also be optimised to consume less energy, making them ideal for battery-powered applications. In the WIKA portfolio, for instance, this pertains to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C isn’t a fieldbus, long wire lengths aren’t recommended. The utmost wire length depends, at length, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where the pressure sensor or the pressure sensor module is built-into the customer product and thus protected against external influences. It will also be noted that with any digitally processed signal, the response time due to discrete-time sampling will undoubtedly be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will be happy to help you with any further questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems
Fill below form and we’ll send you the whitepaper ?Distributed Intelligence?.
Name
Company
E-mail
Send
We?re focused on your privacy. We?ll use your information to contact you about our services. E mail us at socialmedia@wika.com to revoke your permission to use your information.

Leave a Comment